Specifications and models
● -Type working chamber size** ()
Foreword
With the rapid development of modern industrial technology, the application fields of rubber and plastic products are becoming increasingly broad, and the environmental conditions they are subjected to are also becoming more and more extensive. The more complex and diverse. Only by reasonably specifying the environmental conditions of the product and correctly selecting the environmental protection measures for the product can the product be protected from damage during storage and transportation and be safe and reliable during use. Therefore, artificial simulated environmental testing of rubber and plastic products is an indispensable and important link to ensure their high quality. Artificial simulated environmental tests are scientific summaries of actual environmental impacts and have the characteristics of typification, standardization, ease of use, and ease of comparison. The diversification of environmental conditions and the importance of environmental testing also put forward more stringent requirements for environmental testing equipment.
The damage to materials caused by temperature and moisture has attracted people's attention. Today, our industrial technology is becoming more and more developed, and it is also causing more and more serious damage to the natural environment. Various corrosive gases caused by various manufacturing industries are mixed in the air, such as ozone. Its destructiveness is very serious for materials or products. test.
This ozone aging test equipment can be used to deform rubber products such as vulcanized rubber, thermoplastic rubber cable insulation sheaths and other products under static stretching or continuous dynamic stretching deformation, or under alternating intermittent dynamic stretching and static stretching. The sample is exposed to a closed, non-illuminated air containing constant ozone concentration and a constant temperature test chamber for a predetermined time to detect cracks or other changes in properties on the surface of the sample to evaluate the ozone aging resistance of the rubber.
Reference standards
● B Dynamic tensile test method for ozone aging resistance test of vulcanized rubber
● B/ - Static tensile test method for ozone cracking resistance of vulcanized rubber or thermoplastic rubber
● B/ .-.- General test methods for cable insulation and sheath materials
● And test methods specified in other relevant standards
Product use restrictions
This test equipment is prohibited from testing media with the following conditions:
● Testing and storage of flammable, explosive and volatile substance samples
● Testing and storage of corrosive substance samples
● Testing or storage of biological samples
● Strong Testing and storage of electromagnetic emission source samples
Equipment performance parameters
● Temperature range: ℃ ~ ℃
● Temperature uniformity: &;℃
● Temperature fluctuation: &; .℃
● Temperature deviation: &;&;℃
● Humidity range %R
● Humidity uniformity: +%~-%
● Heating and cooling rate: .-. ℃/
● Time setting range: ~. hours
● Ozone concentration: ~
● Ozone concentration deviation: &;%
● Sample rack speed: -r/ (can Adjustment)
● Clamp stretch rate %~% (adjustable)
● Total power:
● Power supply voltage: /
Mechanical sheet metal structure
● Outer wall: Use CNC machine tools to process and form beautiful and generous steel plates with electrostatic spraying
● Inner wall: Use CNC machine tools to process and form stainless steel plates
● Set a transparent window (&;) at a reasonable position on the door to observe indoor samples Changes (with lighting to keep the inside of the box bright) The observation window uses multi-layer hollow tempered glass, which has the advantages of transparency, heat insulation, explosion-proof, etc.
● Uses low-noise, multi-wing centrifugal fans for air circulation to avoid any dead ends. Make the temperature, humidity and ozone evenly distributed in the test area. The air outlet and return air circulation design of the air path meets the test standards, and the wind pressure and wind speed can quickly stabilize the temperature and humidity when opening the door
● The test door and the machine body adopt double-layer ozone-resistant high-tensile silicone sealing strips to Ensure the test area is airtight
● The refrigeration system of the equipment is installed below the working room and the compressor adopts imported Taikang brand
● High-quality fixed movable wheels are installed at the bottom of the instrument to easily move the instrument to the designated location. Finally, fix the instrument
● The control part of the equipment is designed on the right side of the equipment, with temperature controllers, control switches, etc., which are convenient to operate, simple and easy to maintain
● The test space is equipped with a dynamic chamber that can only be used for dumbbell-shaped tests. , Static tensile fixed fixture
Tensile test
The standard stipulates that the two ends of the specimen are clamped on special fixtures. Select an elongation rate for stretching. Generally, % is selected. The fixture is installed on a rotating sample rack. Sample rack rotation speed The test is carried out between (&;)/r at the specified stretching rate of the clamp at the ozone concentration specified at (&;)°C or by cyclic stretching and reset and rotating together with the sample holder. After the specified time, check the cracks of the sample. General ozone concentration selection (&;)&;- The ozone concentration can also be adjusted according to the pre-agreed concentration.
Heating system
● Heating uses far-infrared nickel-chromium alloy high-speed heating electric heating wire
● Heater control method: non-contact periodic pulse width modulation R (solid-state relay)
● The output power is calculated by microcomputer to achieve high efficiency in electricity consumption
Humidification and dehumidification system
● Adopt parallel micro-movement humidification system
● Comes with overheating and overflow double guarantee device
● Water level control uses a mechanical floating ball raft to prevent electronic malfunction
● The control output power is calculated by a microcomputer to achieve high precision and high efficiency in electricity use
● Uses evaporator coil dehumidification method
Refrigeration system
● Refrigeration machine: Using fully enclosed French Taikang high-efficiency and energy-saving air-cooled mechanical compressor
● Refrigeration method: Single-machine refrigeration method
● Fin-type evaporation (also used as a dehumidifier)
● Internal spiral refrigerant copper pipe
● All system pipelines are subject to ventilation and pressurization leak detection tests
● Compressor return air cooling circuit
● Energy regulating circuit
● Refrigerant
● Main components are all made of international high-quality brand products
Electrical control system
● Temperature, humidity, and ozone concentration control instruments are touch screen digital display controllers imported from Canada.
● Direct display of temperature, humidity and ozone concentration
● Display accuracy: .℃ (display range)
● Temperature sensor: platinum resistance tester
● Control method: thermal balance temperature adjustment Method
● Temperature and humidity control adopts system co-ordinated control with the same channel
● Main electrical components adopt French &; Schneider, Japanese &; Fuji, and other brands
Ozone generator
● Ozone The generator is German technology and adopts silent
air-cooled electrode cooling method. The electrode is not hot; this
generator has unique technology: it does not produce nitrogen and oxygen
When the compound ozone is mixed into the water, no bromate ozone will be generated. Device
Generation
● Ozone generation amount: ~
● Electrode cooling method: air cooling
● Ozone generation air supply source: air
Protection system
● Over-temperature protection
● Compressor over-pressure protection
● Compressor overload protection
● Compressor over-current protection
● Water shortage protection
● Power supply phase loss/reverse Phase protection
● Automatically shut down if there is a fault and display the fault content in Chinese
Environmental conditions of use
● The ground should be flat and well ventilated and does not contain flammable, explosive, corrosive gases and dust
● There are no strong electromagnetic radiation sources nearby
● There is a drainage floor drain near the equipment (within meters from the refrigeration unit)
● The load-bearing capacity of the site ground: not less than/
● There is an appropriate maintenance space around the equipment.
● Temperature: ℃~℃
● Relative humidity: &%R
● Air pressure: ~
● /
● Allowable voltage fluctuation range&;%
● The allowable frequency fluctuation range&;%
● The grounding resistance of the protective ground wire is less than - mode power supply or mode power supply
● The user is required to configure a power switch of corresponding capacity for the equipment at the installation site and this switch It must be independent and dedicated to the use of this equipment
● When the equipment is not working, the temperature of the environment should be kept within +~℃. When the ambient temperature is lower than ℃, the water remaining in the equipment should be drained cleanly
Random information
● Operating instructions and circuit diagram.
● Certificate of conformity, warranty card
● Precautions, basic shipping accessories, repair and maintenance matters
Delivery instructions
● The supplier is responsible for the freight. The goods will be shipped within one working day after the prepayment is received;
● % of the total amount prepaid by the buyer within the day after the contract is signed shall be paid in full once the goods arrive and are accepted;
● The supplier is responsible for the installation and debugging operations Introduction until the buyer's employees operate independently;
● The one-year warranty period starts from the date of installation and acceptance. The supplier promises to provide lifetime spare parts after-sales service. If the supplier must go to the site to solve the problem, it will arrive at the user's site within hours.
Nanjing manufacturers sell ozone aging test chambers