Main station|Member Center|Save the desktop|Mobile browsing
Ordinary Member

南京安奈试验设备有限公司

盐雾(交变)腐蚀试验箱、二氧化硫试验箱、高低温试验箱、高低温(交变)湿热试验...

sell
  • There is no classification
contact
  • Contact:臧勤
  • Phone:025-87186835
  • Email:sales@njanai.com
search
 
link
  • There is no link yet
home > sell > Nanjing alternating (composite) salt spray corrosion test chamber manufacturer
Nanjing alternating (composite) salt spray corrosion test chamber manufacturer
products: Views:5Nanjing alternating (composite) salt spray corrosion test chamber manufacturer 
brand: 安奈仪器
工作室尺寸: 600×900×500
温度范围: +15~+60℃
湿度范围: 30%~98%RH
price: 面议
MOQ: 1 台
Total supply:
Delivery date: Shipped within days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2016-05-31 11:28
 
Details
Model Specifications
Model Working Room Dimensions Outline Dimensions Approximate Volume (excluding lid) Pre-installed Power
-
Product Description
This alternating salt spray corrosion test equipment uses salt solution Or acidic salt-containing solutions can be achieved by using this test chamber without moving the test sample in a test chamber: four cycles (alternating) of salt spray, drying, standard atmospheric pressure, constant temperature and humidity, and low-temperature storage. The test effects are based on the material under the test requirements. Or the product undergoes accelerated corrosion testing to measure the degree of damage suffered by the material or product within a certain time range. This equipment is used to assess the resistance to salt spray corrosion, drying, standard atmospheric pressure, constant temperature and humidity, and room temperature storage capabilities of materials and their protective layers, as well as to compare the process quality of similar protective layers. It is an artificial simulation of salt spray corrosion, drying, and standard Tests in atmospheric pressure, constant temperature, humidity and low-temperature storage environments can also be used to evaluate the ability of certain products to resist salt spray corrosion.
Only by reasonably specifying the environmental conditions of the product and correctly selecting the environmental protection measures for the product can the product be protected from damage during storage and transportation and be safe and reliable during use. Therefore, artificial simulated environmental testing of materials or products is an indispensable and important link to ensure their high quality. Artificial simulated environmental tests are scientific summaries of actual environmental impacts and have the characteristics of typification, standardization, ease of use, and ease of comparison.
The salt spray test was first proposed by... The purpose at that time was to obtain test conditions similar to those in the coastal atmosphere to study the reliability of certain metal protective layers. It is to put the sample in salt spray for testing. This is the earliest application of salt spray test.
Our country has produced relevant national standards for this salt spray test and made detailed regulations. It has developed from the initial simple neutral salt spray test to: acetate salt spray test, copper salt accelerated acetate salt spray test Test and alternating salt spray test and other forms. This test chamber is a cyclic test equipment that uses a touch screen to simulate these environmental factors in a box in a fully automatic manner. It also complies with domestic standards and relevant international standards.
This equipment is widely used in enterprises and institutions such as automobiles and motorcycles, military equipment, electrical and electronics, chemical industry and metallurgy, quality inspection and measurement, postal and telecommunications, ships and railways, as well as universities, colleges and scientific research institutions.
Meet the standards
Salt spray test standards. and
Salt spray test standards for electrical and electronic products. and
- "Artificial Atmosphere Corrosion Test Salt Spray Test"
- "Technical Conditions of Salt Spray Test Chamber"
- "Accelerated Tests of Corrosion Cycles of Metals and Alloys Exposed to Salt Spray, Dry and Wet Conditions"
- "Neutral Salt Spray Resistance of Paints and Varnishes" Determination"
.- "Measurement Method for Environmental Parameters of Electrical and Electronic Products"
- "Test of Paint Films to Determine Humidity and Heat Resistance, Salt Spray Resistance, and Weather Resistance (Artificial Acceleration)"
.- "Methods for Detection of Anodic Oxidation Films on Aluminum and Aluminum Alloys Part Part: Copper Accelerated Acetic Salt Spray Test (Test)"
- "Corrosion Resistance Test Methods for Metal Coatings and Chemically Treated Layers of Light Industrial Products Neutral Salt Spray Test ( ) Method"
- "Acetic Salt Spray Test Method for Corrosion Resistance of Metal Coatings and Chemically Treated Layers of Light Industrial Products"
- "Corrosion Resistance Test Methods for Metal Coatings and Chemically Treated Layers of Light Industrial Products Copper Salt Accelerated Acetic Salt Spray Test Method
At the same time, it meets:
standards
technical indicators
. Temperature range: +~+℃
. Humidity range: %~%
. Relative humidity deviation: +~-%
. Temperature deviation: ℃
. Temperature uniformity ℃
. Temperature fluctuation: .℃
/> .Temperature change rate.℃
.Salt spray deposition: ~/d
. Spray method: pneumatic continuous and intermittent spray can be adjusted at will
.Air source pressure: .~< br/> .Test duration: (adjustable)
.Salt water tank volume:
.Internal load-bearing:
.Test mode: fixed value and program test
The test meets the indicators
.Salt spray test: ℃~℃℃ Salt spray deposition amount:~/d The test time can be set. Intermittent or uninterrupted time can be controlled
.Drying temperature ℃~℃℃ Relative humidity %r Time Controllable (setting)
. Constant temperature and humidity: ℃℃ Humidity~%r (Humidity deviation: +~-%r) Time can be controlled (set)
. Low temperature placement: ℃℃ Humidity%r~%r (Humidity deviation: +~-%r) Time can be controlled (set)
Introduction to structural design
The main structural components of this test chamber are: box Body part, air duct part, electrical appliances and control systems, heating systems, refrigeration systems and pneumatic component systems.
. The whole set of equipment has beautiful appearance, reasonable structure, smooth lines, and natural flow. The inner and outer materials of the box are made of high-quality plates, which can withstand high temperatures. The lid of the box is made of high-quality transparent plates, which have a smooth and bright appearance, are corrosion-resistant, easy to clean, and have no leakage. They have good temperature resistance and high strength. Various auxiliary accessories and facilities are also made of temperature-resistant and corrosion-resistant materials and will not cause electrochemical corrosion reaction with the test piece.
.The box cover is designed to open at an optimal top angle so that the condition of the specimen in the room can be clearly observed. The beveled angle of the box cover prevents condensation water generated during the test from dripping onto the sample and affecting the test results.
.The box cover and box body are water-sealed to prevent salt spray from overflowing, which may affect the test results, corrode other equipment in the room, and even cause harm to test operators.
. The spray system uses Hunter's law to spray. It is a tower spray device with a nozzle diameter of ¢. The nozzle is made of pure quartz glass and is durable. The salt spray is distributed uniformly and the sedimentation amount can be adjusted freely without crystallization.
The air source can be compressed air, and the air inlet pressure is MPa using pneumatic components imported from Taiwan to ensure normal use.
.The heating and humidification design of the box is an inner tank water tank heating method with controllable water level and a low water level alarm device. It is environmentally friendly, fast heating, and the temperature and humidity are evenly distributed.
. The sample rack is designed in accordance with national standards to have upper and lower layers tilted by degrees and degrees. Hooks can also be used to facilitate testing of the tested items from all angles.
. The air duct temperature cycle uses a corrosion-resistant long-axis fan motor and a corrosion-resistant multi-wing centrifugal wind wheel to achieve strong convection and vertical diffusion circulation to make the temperature and humidity in the laboratory uniform and stable
. The evaporator for refrigeration of the test chamber also serves as a dehumidifier, which can meet the humidity requirements at different temperatures and undergo anti-corrosion treatment
. This test equipment is equipped with a rapid mist exhaust device. Opening the mist exhaust device at the end of the test can reduce the harm caused by the floating salt spray to the human body and other metal equipment
. There are movable casters at the bottom of the equipment to facilitate moving the entire equipment to a designated location.
Function Introduction
Salt Spray Environment
The continuous salt spray exposure test is widely used to test the corrosion resistance of component surface coatings. Applications include industrial, maintenance, construction and marine coatings plating and paint layers aerospace and military coatings surfaces and components electrical and electronic systems and components.
Most of this test is generally run at higher humidity in accordance with relevant corrosion test standards and is not included in the drying cycle and humidity cycle tests. The test requires the spray air to be preheated before entering the nozzle. Salt spray deposition amount Maintained at: ~/d, it can settle evenly and freely on the surface of each specimen.
Dry environment
During the drying test, the fan works to circulate the hot air in the room and then enters the box. At the same time, the dehumidification system of the equipment discharges the salt spray/moisture in the box out of the box, so that the inside of the box can be generated. low humidity conditions. The temperature of the box is controlled by the box heater and air heater.
Constant temperature and humidity environment
During the constant temperature and humidity function, through bottom heating and humidification, the relative temperature and humidity of the box can be controlled at: temperature ℃ ℃ humidity ~ %r (humidity deviation: + ~ -%r) steam The humidifier, refrigeration system and dehumidification system of the generator maintain the set humidity and are automatically calculated by D intelligent control to achieve the required moist and heat effect.
Low temperature storage environment
Under this environmental condition, the temperature ℃℃ and humidity %r ~ %r (humidity deviation: + ~ -%r) are required. At this time, the heating system, refrigeration system and dehumidification system all need Turning on creates a low-humidity environment to reach the set temperature through hot and cold balance
The applicable air pressure of this environment is standard atmospheric pressure.
Refrigeration system
. Compressor: French Taikang fully enclosed refrigeration compressor
. Refrigeration method: mechanical refrigeration
. Condensation method: forced air cooling
. Refrigerant r or
. All system pipelines are Ventilation and pressure leak detection test of French Taikang refrigeration compressor
. Heating, cooling, moist heat and salt spray systems are completely independent
. Internal spiral refrigerant copper pipe
. Built-in corrosion-resistant finned evaporator.
Control and protection system
.Korea true color LCD touch screen programmable controller
Can automatically operate according to the set curve. It has r interface and
connection to realize test data recording test data And curve recording and - touch screen
Output function Chinese/English human-machine interface (connected to the control computer to achieve real-time monitoring and control The control computer has a network card and interface optional) The touch screen can realize temperature, humidity, time, keyboard lock The integrated control of other functions has a dynamic display function, which can alternately cycle the salt spray test, dry environment, constant temperature and humidity environment and low-temperature storage environment, and realize reset, reset and other functions
. The control accuracy is: .℃
.Temperature measurement sensor: platinum resistance thermometer made in Japan
.Schneider executive components from France
.Using pneumatic components imported from Taiwan
.The heater uses anti-corrosion titanium alloy electric heating tubes
.The heating method adopts solid-state output + D automatic calculation function
. Saturator over-temperature power-off protection: Generally, the set temperature is ℃ or ℃. When it exceeds the instrument set temperature ℃
The equipment automatically cuts off. The power supply stops operating
. Test chamber, saturated low water level, water shortage and power outage protection: The test chamber and saturator are equipped with liquid level switches inside to prevent water shortage
Burning causes equipment damage
. Box body Over-temperature power-off protection: Generally, the set temperature is ~℃ or ℃. When it exceeds the instrument set temperature ℃
the equipment will automatically cut off the power supply and stop running
. Two-stage compressed gas voltage stabilization and voltage regulation protection: Ensure stable gas pressure and gas cleanliness when the supplied gas source enters the interior of the test chamber
. Test operation instructions: The control panel is equipped with a test chamber operation indicator light
. Test end instructions: At the end of the test, the control panel is equipped with a test end indicator light
. No fuse protection switch, low water level, leakage and automatic shutdown and other protection systems
. Salt water high and low water level prompts: visible on the side of the salt water tank Observe the brine level and provide a basis for adding salt solution in a timely manner
. Saturator high and low water level prompts: The external water level indicator of the saturator can provide strong protection against dry burning of the saturator by visualizing the water level.
. Compressor over-temperature protection: The refrigeration compressor is equipped with a high-temperature temperature sensing package. When the temperature is too high, the equipment automatically cuts off power or stops running to protect the equipment and refrigeration system
. Compressor over-pressure protection, etc.: for To prevent the stability of the supplied voltage, the electrical system is equipped with a voltage overload protection device to protect the normal operation of the compressor and play a role in effective operation.
Random information
.Instructions, circuit diagrams, certificates, warranty cards
.Operation methods, precautions
.Basic shipping accessories, maintenance matters.
Equipment usage conditions
.Ambient temperature: +℃~+℃
.Ambient humidity: %
.Power supply requirements: (%)/
. Customers must prepare their own gas source or air compressor
Random accessories
. Special round rod type sample holder, type sample holder
. Standard quartz glass nozzle
. Standard glass funnel
.Standard glass metering cylinder
.Specially designed tower or wall-mounted spray tower
.Mist collecting cover
.Silicone tube and other related accessories
.Salt spray mist exhaust Hose
.Sodium Chloride Analytical Pure
Delivery Instructions
.The supplier is responsible for door-to-door delivery and will be shipped within one working day after the prepayment is received
.The buyer pays in advance % of the total amount, the balance shall be paid in one lump sum after the goods arrive and are accepted and accepted
. The supplier is responsible for the installation, debugging and operation introduction until the demander’s employees operate independently
. The one-year warranty period starts from the date of installation and acceptance. . The supplier promises to provide lifelong after-sales service of spare parts and must go to the site to solve the problem. The supplier will arrive at the user's site within hours.
The above data are measured under no-load conditions in the ambient temperature ℃ d studio. The temperature and humidity performance test can be tested in accordance with national standards and relevant provisions.
Request for quotation
A total of0articles  Related Comments: